MANUFACTURER : Scheftner Dental Alloys
Advantages for users:
- Ideal mechanical properties
- Excellent bonding with ceramics for titanium
- Biocompatible
- Extremly corrosion resistant
- Particularly patient friendly due to low thermal conductivity
- Perfect suitable for implant-supported restorations, superstructures, bars and abutments
| Composition in percent by mass | |
| Ti | 89.40% |
| Al | 6.20% |
| V | 4% |
| N,C,H,Fe,O | <0.4% |
|
Technical properties: |
|
| Proof stress (Rp 0.2) | 837MPa |
| Ultimate tensile strength | 921MPa |
| Elongation | 15% |
| Vickers hardness | 330HV5/30 |
| Density | 4.4g/cm³ |
| Melting point | 1650°C |
| CTE (20-600°C) | 10.3 x 10⁻⁶K⁻¹ |
| Type (DIN EN ISO 22674) | 4 |